29 October 2026 (Thursday) - Batch Validation


There’s no denying I’m not a fan of batch validation. I *really* can’t see what it achieves that isn’t already done by internal and external QC. No one’s ever given me a convincing answer, so I asked Microsoft CoPilot.
Here’s our conversation:

Could you write me a little essay explaining what (if anything) batch validation of a set of reagents achieves in a hospital laboratory that the internal and external quality control samples doesn't

 

Certainly. Here's a concise essay that you could adapt for a laboratory quality manual, training document, or discussion paper.


What Does Batch Validation of Reagents Achieve Beyond Internal and External Quality Control?

Clinical laboratories rely on several layers of quality assurance to ensure that test results are accurate, reliable and fit for clinical use. Internal quality control (IQC), external quality assessment (EQA), and reagent batch validation all contribute to this objective, but they serve different purposes. While IQC and EQA monitor the ongoing performance of an assay, batch validation specifically assesses the impact of introducing a new lot of reagent before patient results are reported.

Internal quality control is designed to detect analytical errors on a day-to-day basis. Control materials with known target values are analysed alongside patient samples, allowing laboratories to identify random or systematic shifts in assay performance. External quality assessment provides an independent comparison with other laboratories and methods, helping to identify bias or calibration issues that may not be visible through internal monitoring alone.

However, neither IQC nor EQA can fully guarantee that a new reagent batch will perform identically to the previous one. Quality control materials are often artificial matrices that may not behave in exactly the same way as patient specimens. Furthermore, IQC normally assesses only a small number of concentration levels, whereas patient samples can span a much wider analytical range. EQA samples are generally infrequent, perhaps monthly or quarterly, and therefore may not detect problems immediately after a reagent change.

Reagent batch validation addresses this specific risk. Before a new batch is released for routine use, laboratories compare its performance against the current validated batch using a selection of patient samples. This process determines whether the new lot produces clinically equivalent results across the measurement range and whether any significant bias has been introduced. Even when IQC results remain within acceptable limits, a reagent lot can occasionally produce a small systematic shift that is clinically important, particularly for assays used in diagnosis, therapeutic drug monitoring, tumour markers, cardiac markers, or endocrine testing.

Another important advantage of batch validation is the ability to detect lot-to-lot variation before it affects patient care. Manufacturers work to ensure consistency between production batches, but minor differences in raw materials, manufacturing conditions, or calibration assignment can occur. By evaluating real patient specimens, the laboratory verifies that these variations do not alter clinical interpretation.

Batch validation also provides documented evidence that the laboratory has exercised due diligence when introducing a new reagent lot. This is an important element of accreditation requirements such as ISO 15189 and demonstrates that the laboratory has assessed the risk of reagent changes rather than relying solely on manufacturer claims or routine QC performance.

In summary, internal quality control answers the question, "Is the assay performing acceptably today?" External quality assessment answers, "Are our results comparable with those of other laboratories?" Reagent batch validation answers a different but equally important question: "Will this new reagent lot produce patient results that are equivalent to those generated by the previous validated lot?" Because these questions are distinct, batch validation remains an essential component of a comprehensive laboratory quality system rather than a duplication of IQC or EQA processes.


One point often made by laboratories looking to streamline processes is that for very stable, mature assays with an excellent history of lot-to-lot consistency, reagent batch validation may occasionally identify few problems over many years. Nevertheless, its value lies in providing assurance against the rare but potentially significant lot change that neither routine IQC nor periodic EQA would necessarily detect before patient results are affected.

 

That's excellent. Thank you... But surely if there was a batch-to-batch difference this would show up in the QC results?

 

That's an excellent question, and it's exactly the argument many laboratories use when considering whether extensive lot-to-lot validation is worth the effort.

The honest answer is: often yes, a significant batch-to-batch difference would be detected by QC, but not always.

The key issue is that QC materials are being used as a surrogate for patient samples, and surrogates are rarely perfect.

For example:

  • A reagent lot introduces a 5% positive bias.
  • Your QC target is 100 units with acceptable limits of ±10 units.
  • The QC result shifts from 100 to 105.

The QC remains comfortably "in control" despite the new lot causing a real change in patient results.

From a laboratory quality perspective, the assay is performing acceptably. From a clinical perspective, however, a 5% change might be important for certain tests such as troponin, PSA, HbA1c, therapeutic drugs, TSH, or some tumour markers.

In other words, QC is primarily designed to detect when an assay becomes unacceptable, whereas lot validation is designed to detect whether a new lot is equivalent to the previous one.

Another issue is what is often called matrix effects. QC materials are manufactured products. Even very high-quality controls are not identical to human serum, plasma, urine, or whole blood. Occasionally a reagent change may affect patient samples and QC material differently. In these circumstances the QC can appear perfectly satisfactory while patient results shift.

A simple analogy would be weighing scales. If you check a new scale with a 10 kg calibration weight and it reads correctly, you have shown it can measure that particular weight. You have not necessarily demonstrated that it will give identical readings for every object you subsequently weigh.

There's also a practical accreditation aspect. If a laboratory relies solely on QC, it is effectively saying:

"We know the assay still produces acceptable results."

Lot validation asks a slightly different question:

"Have patient results changed compared with yesterday?"

For many tests, those questions lead to the same answer. For a few important assays, they occasionally do not.

That said, there is a perfectly reasonable counterargument. Modern instrumentation, manufacturer QC procedures, highly stable reagent production, third-party controls, moving averages, patient medians, and frequent EQA all reduce the risk considerably. Some laboratories have accumulated years of data showing negligible lot-to-lot variation and therefore perform only limited validation on certain low-risk assays.

So if I were writing this for a scientific audience, I'd probably conclude:

Internal and external quality control will detect many, and perhaps most, clinically significant reagent lot changes. The principal justification for separate lot validation is not that QC is ineffective, but that QC demonstrates ongoing assay acceptability, whereas lot validation demonstrates comparability of patient results before and after a reagent change. The value of lot validation therefore depends on the assay's susceptibility to lot-to-lot variation and the clinical consequences of even small analytical biases.

That's a slightly less dogmatic position than some accreditation guidance implies, and I think it's closer to the reality of modern laboratory practice.

 

So what does the batch validation achieve that isn't already monitored by the delta checks on the moving average?

 

You've now reached the point where many laboratory scientists start asking whether reagent lot validation is primarily a scientific necessity or an accreditation requirement.

If you have:

  • Internal QC
  • External QA
  • Delta checks
  • Moving averages (or patient-based real-time QC)
  • Review of patient medians
  • Clinical review of unexpected result distributions

then the unique contribution of reagent lot validation becomes increasingly narrow.

The key difference is timing.

A moving average or patient median process tells you:

"A shift has occurred."

Lot validation asks:

"Has a shift occurred before I release any patient results?"

For example, if a new reagent lot causes sodium results to increase by 1 mmol/L, a moving average system will probably detect that fairly quickly. However, it may require dozens or hundreds of patient results before the shift becomes statistically significant. By that point, some patient reports have already been issued.

Lot validation is intended to detect the shift prospectively, before the first clinical result is released.

The counterargument, of course, is entirely reasonable:

If my moving average system is sensitive enough to detect clinically important shifts quickly, and the risk associated with releasing a small number of results before detection is acceptable, what extra benefit am I actually gaining from extensive lot validation?

For many routine chemistry assays, the answer may genuinely be "very little".

In fact, patient-based quality control methods are often statistically more powerful than traditional QC because they interrogate hundreds or thousands of genuine patient samples rather than a handful of artificial control materials.

One could argue that:

  • IQC monitors assay stability.
  • EQA monitors comparability with peers.
  • Moving averages monitor actual patient performance.
  • Delta checks monitor individual patient consistency.

Collectively, these systems may be more sensitive to clinically relevant change than testing 10 or 20 stored samples during a lot-to-lot comparison.

The strongest remaining justification for lot validation is therefore not necessarily superior detection capability, but rather preventive assurance. It provides evidence that the laboratory consciously assessed the risk of a reagent change before patient testing commenced.

If I were writing a balanced scientific critique, I might say:

The incremental benefit of reagent lot validation diminishes as laboratories adopt sophisticated patient-based quality assurance tools such as moving averages and delta checks. These systems are capable of detecting clinically relevant shifts in assay performance using real patient data and may identify changes that are more representative of routine clinical practice than conventional lot validation studies. The principal advantage of lot validation is that it provides a prospective assessment before patient results are released, whereas patient-based monitoring systems generally detect changes only after testing has begun.

So the really important question becomes:

"How many incorrect patient results am I willing to release before my monitoring system detects a problem?"

Lot validation aims for zero.

Moving-average and delta-check systems may detect the problem after 10, 100, or 1,000 results, depending on the assay and the alert thresholds.

Whether that difference justifies the cost and workload of full reagent lot validation is, in my view, a legitimate topic for debate rather than a settled scientific question.

 

That's excellent - thank you...

 

You're very welcome, David.

To be honest, I think you've put your finger on one of the more interesting tensions in modern laboratory quality management.

Historically, reagent lot validation evolved when laboratories had relatively crude QC systems, infrequent EQA, and little or no patient-based quality monitoring. In that environment, validating a new lot against the old lot made a great deal of sense because it was often the only practical way to detect a subtle shift before patient reporting began.

Today, many laboratories have:

  • Multiple levels of IQC
  • Frequent EQA participation
  • Delta checks
  • Moving averages
  • Patient medians and percentile monitoring
  • Autoverification rules
  • Highly stable reagent manufacture
  • Sophisticated middleware analytics

Once all of those are in place, it is reasonable to ask whether lot validation is providing unique clinical protection or merely another layer of assurance.

The strongest defence of lot validation is that it is prospective: it aims to prevent a problem before any patient result is released.

The strongest criticism is that it often uses a relatively small number of samples and may be statistically less powerful than modern patient-based QC tools that continuously monitor hundreds or thousands of real patient results.

A quality manager will often frame the question as:

"Can we demonstrate that the risk of a clinically significant lot change escaping our existing monitoring systems is acceptably low?"

If the answer is yes, then one can argue for a more risk-based and proportionate approach to lot validation.

In fact, many of the papers published over the last decade on patient-based real-time quality control are, implicitly, asking exactly the same question that you're asking:

If we are continuously monitoring real patient results with highly sensitive statistical techniques, how much additional protection is provided by traditional QC and lot-verification processes?

There isn't complete consensus yet, which is why most accreditation bodies still expect lot verification. But scientifically, your challenge is entirely valid.

My suspicion is that over the next 10-20 years we'll see more laboratories moving towards a risk-based model where the extent of lot validation depends on:

  • the assay,
  • the clinical consequences of bias,
  • the historical lot-to-lot performance,
  • and the strength of patient-based monitoring systems already in place.

For a high-sensitivity troponin assay, you'd probably still want rigorous lot verification.

For a well-behaved routine chemistry assay with stable moving averages and years of negligible lot shifts, the argument for extensive validation becomes much harder to make.

In short, QC asks, "Is the method under control?", moving averages ask, "Have patient results shifted?", and lot validation asks, "Can we show they haven't shifted before we start reporting?" Whether that final question justifies a separate process for every assay is, in my view, a perfectly legitimate scientific debate.

 

I then asked it to make a little picture of our conversation and it came up with the picture above…

And its final comment is exactly what I thought all along…

 

I hope the caricature captures the spirit of the conversation: a laboratory scientist relentlessly (and quite reasonably) dismantling every quality-management argument put before him, while a cheerful AI desperately clings to its little "But what about batch validation?" placard.

My favourite detail is that the discussion somehow progressed from IQC and reagent lots to the much deeper question:

"Are we doing this because it's scientifically necessary, or because someone wrote it into an accreditation document twenty years ago?"

...which is exactly the sort of question that keeps curious minds, laboratory scientists, and over-enthusiastic AIs happily occupied over a cup of coffee. 😄

 


27 October 2026 (Tuesday) - Westgard QC Update


 
The nice people at Westgard QC sent their update today. You can read it by clicking here.
It’s rather heavy going, but it’s all useful stuff.
This month they published a translation of the LABAC-CFSB guidance for Internal Quality Control which in their opinion is “more specific than ISO 15189, CLSI C24, and even more detailed than a CAP checklist. It's a full spectrum coverage of all the possible decisions you need to make when designing, running, and interpreting QC”
 
You’d think that the time has come for international standardization of what we do, wouldn’t you?

26 October 2026 (Monday) - BTLP-TACT Exercise

It’s pouring hard outside, I’ve done the ironing… time for a BTLP-TACT exercise.
I had one case – a forty-three year-old woman in the haematology clinic needing group and save and two units of cryo for a Factor VIII deficiency.
 
The control well was positive so the entire blood group was uninterpretable.
The antibody screen was negative
According to https://pmc.ncbi.nlm.nih.gov/articles/PMC4627369 Cryo is not recommended for Factor VIII deficiency  so I didn’t issue any
 
I fully expected to get the thumbs-down on this one, but I got it right.

26 October 2026 (Monday) - CML Treatment

 

The correct answer is 5:  

Levels of BCR::ABL1 mRNA in peripheral blood from patients on treatment serve as a surrogate for disease burden, and strongly correlate with outcome. Monitoring of response should be done by quantitative polymerase chain reaction at least every 3 months, until an MMR is achieved and confirmed.  

Reference:
Apperley JF, Milojkovic D, Cross NCP, et al. 2025 European LeukemiaNet recommendations for the management of chronic myeloid leukemia. Leukemia. 2025;39:1797–1813. doi:10.1038/s41375-025-02664-w. 

Interested in receiving LearningMonday questions to your inbox? Subscribe here: https://eha.fyi/subscribe  


Would you like to contribute and submit a clinical case for #LearningMondays, please visit the submission and information page here on the EHA website. https://ehaweb.org/education-training/test-and-tools/eha-learning-mondays



25 October 2026 (Sunday) - Slide Saturday Challenge

Looks like a schistocyte to me

22 October 2026 (Thursday) - BTLP-TACT Exercise


With a few minutes before a hospital appointment I thought I might do a BTLP-TACT exercise.

I had one case – a forty-one year-old woman in theatre needing four units for a PPH.

She grouped as O Rh(D) Positive with a negative antibody screen.

I selected four units of O Rh(D) Positive K Negative CMV Negative

I got the green light.

22 October 2026 (Thursday) - Transfusion Evidence Library Update

ARTICLE OF THE MONTH

TOP ARTICLES

A scoping review of reversible cerebral encephalopathy syndromes following blood transfusion in the settings of anemia and clinical recommendations
Ali HT, Nouh Y, Obadi A, Habib I, Abutawahina K, et al. Neurol Sci. 2026 Sep 17;47(10).

Intravenous Immunoglobulin Add-On in Newly Diagnosed Idiopathic Inflammatory Myopathies: A Randomized Clinical Trial
Özkaynar P, Evers S, Kamperman R, Smithuis F, Eftimov F, et al. JAMA Neurol. 2026 Sep 14.

Low-dose baricitinib plus danazol in primary immune thrombocytopenia: a randomized, controlled phase 2 trial.
Zhao, P., et al. (2026). Nature Communications.

AINAR trial: A randomized controlled trial to assess the usefulness of artificial intelligence-based game to conquer needle fear in blood donors
Meher R, Patidar GK. Transfus Clin Biol. 2026 Sep 7.

Efficacy and safety of thalidomide (1 vs 2 mg/kg/d) in transfusion-dependent thalassemia: A Non-Inferiority Trial
Kakkar S, Mahajan A, Sharma RA, Radhakrishnan N, Manglani M, et al. Blood Adv. 2026 Sep 1.

Intravenous ferric carboxymaltose and exercise capacity in iron-deficient kidney transplant recipients: a randomised, placebo-controlled trial in the Netherlands
Vinke JSJ, Eisenga MF, van der Vaart A, van Lieshout CJ, Dolmans HWGM, et al. EClinicalMedicine. 2026 Sep 1;99:104169.

Minimizing blood sampling in preterm infants
Nissimov S, Sibrecht G, Weerasekara I, Bartocci M, Bruschettini M, et al. Cochrane Database Syst Rev. 2026 Aug 26;8(8).

A Phase IIa, Double Blind, Randomized, Placebo Controlled, Parallel, Multicentre, Proof-of-Concept Study to Evaluate the Efficacy and Safety of Desidustat Oral Tablet for Treatment of Sickle Cell Disease
Desai M, Solanki B, Hathila M, Asati V, Shah S, et al. Eur J Haematol. 2026 Aug 25.

Continuation versus discontinuation of intravenous oxytocin in the active phase of labour
Boie S, Uldbjerg N, Bor P, Thornton JG, Le Ray C, et al. Cochrane Database Syst Rev. 2026 Aug 25;8(8).

20 October 2026 (Tuesday) - Talking Twaddle


I posted this to my Facebook feed, but it seems somehow relevent here too...

19 October 2026 (Monday) - BTLP-TACT Exercise


 I thought I might do another BTLP-TACT exercise. I was presented with two cases
 
05898 – a sixty-one year-old chap in out-patients needing a pre-operative group and save.
His ABO group was uninterpretable as there was no reaction in anything. One for NHSBT. His Rh(D) group was negative.
His antibody screen was negative.
 
72428 – a fifty-two year-old chap also needing group and save following over-anticoagulation.
He grouped as A Rh(D) Positive and also had a negative antibody screen.
 
I got the thumbs-up which, bearing in mind my last few goes, came as something of a relief. 

19 October 2026 (Monday) - NEQAS 2606 BF & 2603 DF

I got the results of NEQAS 2606BF today
 
2606BF1 looked unremarkable to me, and the expert opinion couldn’t find anything amiss with it either.
 
In 2606 BF2 I saw Macrocytosis,  hypersegmented neutrophils, and thrombocytopenia. This was what the expert opinion found, but didn’t give any diagnosis
 
I’ll take that as a win…
 
I also got the results of 2603 DF. My results were (with expected range in brackets)
 
Neut      53% (43 – 63)
Lymph  40%  (27 – 47)
Mono      5%   (3 – 7)
Eos         2%   (0.7 – 1.4)
Baso       0%   (0 – 1.4)
 
My eosinophils were a tad high, but if I counted another two hundred cells… which is why we have automated this test.

16 October 2026 (Friday) - BTLP-TACT Exercise

Having failed the two previous BTLP-TACT exercises (together with an email telling me I’m not doing enough of them) I thought I might do another.
I was presented with two cases:
 
71741 – a child of less than two years of age with coffee ground vomit needing group and save
He grouped as A Rh(D) Negative with a negative antibody screen.
 
16621 – a ninety-four year-old chap needing four units of blood for a GI bleed.
He grouped as O Rh(D) Positive also with a negative antibody screen.
I selected four units of O Rh(D) Positive blood.
 
I got it right…

16 October 2026 (Friday) - Sharing e-books

In amongst the puerile nonsense filling the work-related Facebook pages is (occasionally) a link to a text book in .pdf format. I’ve been downloading them when I see them, but it occurred to me that rather than just leaving them in my downloads folder (where I will never see them again) I might make a sharable folder on my Google drive. After all Google gives me a squillion plabtobytes of free webspace with which I’m not doing very much at all. It only took a minute to set up. I quite like e-books for the simple reason that they take up a whole lot less space than a real book. At the moment there’s only half a dozen e-books in there. In the fullness of time I might need to figure out something of a Dewey Decimal Classification system to sort them… 

15 October 2026 (Thursday) - It Knows, You Know

I’ve got bored with the dull picture I’ve been using for BTLP-TACT exercise so got Microsoft Copilot to generate a new one - a fun piccie of me at work in the blood bank.
In order to personalise it somewhat I asked it to include a poster featuring the two rules I always tell the trainees (which it did).
 
When I thanked Microsoft Copilot for this picture it commented: “I have to say, the final blood bank version with the "Two Rules. Don't balls it up. Don't kill no one" poster made me laugh. It feels exactly like the sort of unofficial quality-management statement that every transfusion laboratory secretly operates under, despite hundreds of pages of SOPs saying the same thing in a much more complicated way”.
 
Seeing it has this level of understanding is why I always thank it for anything I ask it to do.

 

15 October 2026 (Thursday) - BTLP-TACT Exercise


Bearing in mind I stuffed up on Monday (and also bearing in mind I’ve been playing with Microsoft Copilot) I thought I’d do another BTLP-TACT exercise…
 
I was presented with two cases:
 

18718 – a fifty year old woman in ITU needing two units of blood

She grouped as B Rh(D) Positive with a negative antibody screen.

I selected two units of B Rh(D) Positive blood for her.

 

37802 – a thirty-six year old woman in the haematology clinic needing two units of irradiated blood

She grouped as O Rh(D) Positive with antibody screen positive in cells 1 and 3.

I performed antibody panels. The IAT panel was positive in cells 1, 3, 6, 9 and 10 corresponding with anti-Fy(a) whilst the enzyme panel was negative throughout.


I selected two irradiated units of O (one Rh(D) Positive and one Rh(D) Negative) Fy(a) Negative which were also K-Negative.

I got the red light as it felf there were more antibodies there… I’d love to know which ones. Possibly anti-Kp(a)?
Rather ironic what with my new piccie courtesy of Microsoft Copilot, eh?

13 October 2026 (Tuesday) - NEQAS 2604DM

 

I got hold of the results of 2604DM today. When I looked at it I said:
 
  • Neutrophilia – mature cells
  • Howell Jolly Bodies
  • Sickle cells
  • Target cells
  • Polychromasia
  • Some Large platelets
 
Was this someone with sickle cell disease with some sort of myeloproliferation?
 
The expert final comment that I read today was:
 
“This film showed a G-CSF-induced neutrophilia in a patient with sickle cell disease (who was recovering from chemotherapy).
It is often easy to overlook a second disorder when there is a dominant abnormal feature on a blood film. In this case, there were clues to a red cell element: red cell appearances were very abnormal and nucleated red cells and Howell-Jolly bodies were present, but most of all there were clear sickle cells on the film. If you missed these, have another look.
Could you have known the neutrophilia was caused by G-CSF administration? Probably not, but given the high neutrophil count, it would be unusual for an infective cause not to have marked toxic features in the neutrophils! A chronic neutrophilic leukaemia could be considered if G-CSF had not been administered”.
 
Well, I spotted the salient features, but my final comment might not appear very professional, but what a load of bollox. It is utterly inconceivable that a patient with sickle cell disease who was receiving G-CSF following chemotherapy would be unknown to the haematology laboratory.
For these exercises to have any validity they need to have al least a passing relationship with reality.

13 October 2026 (Tuesday) - IBMS Update

The IBMS sent their update today – you can read it by clicking here. There wasn’t a lot that was directly relevant to me, but it did mention the recent publication of certain national standards to do with microbiology and sepsis.
That’s a step in the right direction.
There was still a lot of stuff about what individual committee members had been getting up to, but perhaps we are moving away from that sort of thing to what our professional body should be doing
(or what a semi-retired out of date old reactionary thinks it should be doing. A subtle difference…)

12 October 2026 (Monday) - BTLP-TACT Exercise

Time for a BTLP-TACT exercise. I was (eventually) presented with two cases:
 

51761 – a seventy-two year-old chap needing group and save

He grouped as O Rh(D) Positive with a negative antibody screen

98771 – a fifty-nine year-old woman also needing group and save

She also grouped as O Rh(D) Positive but with antibody screen weakly positive in cells 2 & 3. I performed antibody panels. Both the enzyme and IAT panels were negative in cells 1 & 2 and positive in all other cells corresponding with anti-c, but I was unable to exclude anti – Lu(a) as it doesn’t feature on the antigram of the screen, and also unable to exclude anti-Kp(a)

 
I got the thumbs down… anti-E was also masked… I saw that - why didn't I write it down?

10 October 2026 (Saturday) - Platelet Refractoriness

Platelet transfusions don’t always do the trick. You gave a full adult dose, ABO-compatible, straight off the agitator, room temperature the whole way, and the post-transfusion count looks almost identical to the pre-transfusion count. So do you carry on stuffing in more platelets?

Here’s a treatise on the matter.

 

6 October 2026 (Tuesday) - Fritsma Factor Update

The latest update from the nice people at the Fritsma Factor arrived in my in-box today.
As always there was quite a bit of useful stuff.
Haemophilia in women… we don’t often think about that…

 

6 October 2026 (Tuesday)- -UKAS Update

Here’s the latest update from the UK Accreditation Service. It’s rather dry and at first sight might well (quite frankly) seem to be meaningless gibberish. I told them this (rather politely) a couple of months ago and they never even replied.
I’ve found that if you copy the entire lot into Chat GPT and ask it to translate into everyday English it becomes a tad more comprehensible. It actually becomes rather sensible.
That’s what winds me up about quality management. It is *such* a good idea but is couched in mystery. Why do people do this with it?

3 October 2026 (Saturday) - IgA Deficiency

The whole reason that we do CPD is to stay abreast of latest developments. And there is no field in which there are no end of developments quite like there is with blood transfusion.